Fridge repairs

Fridge running but not cooling: a diagnosis order

A warm fridge with a running compressor has a short list of likely causes. Working through them in order avoids paying for parts you did not need.

Start with airflow and heat rejection

A condenser packed with dust, or a fridge boxed into a sealed cupboard, cannot reject heat. Before any gas is touched, the condenser and the ventilation around the appliance should be checked.

Then the door and the defrost

A hard, split or misaligned seal lets warm air in continuously. A defrost fault ices the evaporator so no air reaches the food, which looks like a cooling failure but is a control or heater problem.

Only then the sealed system

If the compressor runs, the condenser is clean and the evaporator is clear, pressure readings tell you whether the circuit is short of refrigerant. At that point a leak has to be found, not just topped up.

Questions owners ask