Freezer rooms

Freezer room recovery after a power interruption

A freezer room that has been off for a few hours is not automatically a loss, but the decisions taken in the first hour after power returns decide whether the stock survives.

Check before you open the door

Read the room temperature and the product temperature before opening anything. If the room has held below minus 18°C, the stock is likely sound and the priority is restarting the plant. If it has risen well above that, open the door and assess rather than guessing.

Restart properly

Some systems need a delay before the compressor restarts, and starting several units at once can trip a supply that is still settling. Bring plant on in sequence, confirm the fans and condenser are running, and watch the pull-down rather than assuming it is working.

Prevention is cheaper

Temperature logging with an alarm, door seals in good order and a room that is properly insulated buy time. A room that recovers in two hours instead of eight is the difference between a repair and an insurance claim.

Questions owners ask

012 546 5996084 690 1545Quote